Nothing sets the day off badly like a cold shower. No hot water, or a boiler that has stopped heating the house, is one of the most common calls we get, especially in winter. The good news is that a surprising number of causes are simple. This checklist takes you through them in the order that saves the most time.
Check the boiler for a fault code, look at the pressure gauge (usually between 1 and 1.5 bar when cold), and make sure the power, gas and programmer are on. In freezing weather, check for a frozen condensate pipe. If you smell gas, leave and call 0800 111 999. Never remove the boiler casing: gas work is for a Gas Safe registered engineer.
Need someone now? Call 02034112027 Answered 24 hours a day
Do not use switches, lighters or phones near the smell. Open doors and windows, turn off the gas at the meter if it is safe to do so, and leave the property. Call the National Gas Emergency Service on 0800 111 999. It is free and open 24 hours a day. The same applies if a carbon monoxide alarm sounds.
Check 1: is it everything or just one tap?
If only one tap has no hot water, the problem is probably the tap, a mixer cartridge or an isolation valve. If hot water is missing everywhere, carry on down the list.
Check 2: does the boiler have power?
Look at the display. If it is blank, check that the boiler is switched on at its wall switch or fused spur, and that your consumer unit has not tripped. If the room thermostat or programmer is battery powered, replace the batteries.
Check 3: is gas reaching the boiler?
Try your gas hob. If it works, gas is coming into the house. If you have a prepayment gas meter, check the credit and emergency credit. Also check that the gas valve to the boiler is open: the handle should sit in line with the pipe.
Check 4: read the fault code
Most modern boilers show a code or a flashing light when something is wrong. Note it down and look it up in the manual. It often points straight to the problem, such as low pressure, no flame or a frozen condensate pipe, and an engineer will want to know it. Resetting the boiler once, as the manual describes, is normally fine.
Check 5: look at the pressure
Find the pressure gauge. When the system is cold, the needle should normally sit between about 1 and 1.5 bar, but your manual is the final word. Below 1 bar many boilers will lock out. Some can be topped up using the filling loop, and your manual shows how. If the pressure drops again within days, there is a leak, and it needs an engineer. If it rises above about 3 bar, switch the boiler off and call for help.
Check 6: timer, thermostat and settings
Check that the programmer is not in an off period, that the hot water is switched on, and that the thermostat is set higher than the room temperature. Some boilers have separate winter and summer or hot water modes, and a nudge to a dial can switch hot water off.
Check 7: a frozen condensate pipe
In freezing weather, this is one of the most common causes of a boiler shutting down. Condensing boilers drain waste water through a plastic pipe, usually to the outside. If it freezes, the boiler locks out, often with a gurgling sound or a fault code.
- Find the pipe where it leaves the house. It is usually white or grey plastic.
- Pour warm water, not boiling, over the frozen section. A hot water bottle or warm cloth also works.
- Once it has thawed, reset the boiler as the manual describes.
If the pipe is out of reach, or the boiler still will not start, call an engineer. Our guide to frozen pipes has more on thawing safely.
Check 8: systems with a hot water cylinder
If you have a tank in an airing cupboard, check that the immersion heater switch or fused spur is on and that the cylinder thermostat is set to around 60 degrees. If your boiler fails, an immersion heater can give you hot water while you wait for a repair.
What not to do
- Do not remove the boiler casing.
- Do not touch gas pipes, valves or burners.
- Do not drain the system or tamper with the pressure relief valve.
Work on gas appliances must be done by a Gas Safe registered engineer. Ask to see their Gas Safe ID card, and you can check it on the Gas Safe Register.
What an engineer commonly finds
If none of the checks fix it, the usual culprits are a faulty diverter valve, a failed pump, a circuit board or sensor fault, an airlock or sludge in the system, or a leak that keeps lowering the pressure. An engineer can diagnose these quickly, and many repairs are done in one visit.
Is it an emergency?
A cold shower is inconvenient, not dangerous. Treat it as an emergency if you smell gas, a carbon monoxide alarm sounds, water is leaking from the boiler, or the household includes babies, elderly people or anyone with a health need, particularly in freezing weather.
When to call us
If you have run through the checks and still have no hot water, call us at any hour. We answer 24 hours a day and send a vetted, insured plumber, usually within 30 to 60 minutes. Where gas work is needed, we will tell you what is required and who must carry it out.
Common questions
Why do I have heating but no hot water?
On a combi boiler this often points to a faulty diverter valve, which switches heat between the heating and the hot water. On a system with a cylinder it can be the cylinder thermostat, a motorised valve or the immersion heater. These need an engineer.
What should my boiler pressure be?
Most boilers sit between about 1 and 1.5 bar when cold, but check your manual. Below 1 bar the boiler may lock out. If the pressure keeps dropping after you top it up, there is probably a leak and you should call an engineer.
Is it safe to reset the boiler more than once?
Resetting once, as your manual describes, is normally fine. If it locks out again, it has a fault, and repeated resets can hide a problem that needs attention.
Is my landlord responsible if I have no hot water?
In most rented homes in England and Wales, landlords are responsible for the heating and hot water installations. Tell your landlord or agent in writing straight away, and check your tenancy agreement.